Ambika
manufactures and supplies products of highest
quality in adherence with the BS, ES, ISO 9000
series of quality systems. The production
facilities is constantly upgraded. Our
physical, chemical and sand testing laboratory
are most up to date and we keep record of all
the testing as per ISO 9000 requirements. We
have in- house pattern making and light
machinery arrangements for faster services to
our customers. We are also in process of
obtaining ISO 9001 certification. |
|
The
appropriate class of manhole top or gully to to
be used depends upon the place of installation.
The various places of installation have been
divided into groups numbered 1 to 6, as listed
below.
The
figure shows the location of some of these
groups in a highway environment. A guide as to
which class of manhole top or gully should be
used is shown in parentheses for each group. The
selection of the appropriate class is the
responsibility of the designer. Where there is
any doubt, the stronger class should be
selected.
Group
1 (min. Class A 15)
Areas which can only be used by pedestrians and
pedal cyclists.
Group
2 (min. Class B 125)
Footways, pedestrian areas and comparable areas,
car parks or car parking decks.
Group
3 (min. Class C 250)
For gully tops installed in the area of kerbside
channels of roads (as per figure) which when
measured from the kerb edge. extend a maximum of
0.5 m into the carriageway and a maximum of 0.2
m into the footway.
Group
4 (min. Class D 400)
Carriageway of roads (including pedestrian
streets), hard shoulders and parking areas, for
all types of road vehicles.
Group
5 (min. Class E 600)
Areas imposing high wheel loads e.g. docks,
aircraft pavements.
Group
6 (min. Class E 900)
Areas imposing particulars high wheel
loads, e.g. Aircraft pavement.
Materials
6.1
General
6.1.1 Manhole tops and gully tops
Manhole tops and gully tops with the exception
of grantings of granting shall be made from
either:
a) flake graphite cast iron.
b) spheroidal graphite cast iron.
6.2
Production, quality and testing
The production, quality and testing of the
materials designated below shall comply with the
following ISO standard or Euronorms:
Flake graphite cast iron
ISO
185 1988
Spheroidal graphite cast iron
ISO
1083 1987
Design
Requirement
7.1
General
Gully tops and manhole tops shall be free of
defects which might impair their fitness for
use.
Where there is no detailed specification shown
in this standard for any particular requirement,
the manufacturer shall state such specification
in his documentation.
7.3
clear opening of manhole tops for man entry
The opening of manhole tops designed for man
entry shall comply with the safety requirements
in force at the place of installation. Generally
this is considered to be at least 600 mm
diameter.
7.4
Depth for insertion
Gully tops and manhole tops of classes D 400, E
600 and F 900 shall have a depth of insertion A
(see Clause 3, No. 12) of at least 50 mm.
This requirement does not apply if the cover or
grantings are made secure in their position
against displacement by traffic by a locking
device but such devices are not included in this
standard.
7.6
Seatings
The manufacture of gully tops and manholes tops
shall be such as to ensure the compatibility of
their seatings. For classes D 400 to F 900 these
sitting shall be manufactured in such a way as
to ensure stability and quietness in use. This
may be achieved by machining of the contact
surfaces, use of cushioning inserts, threepoint
suspension design or any other appropriate
method.
7.9
Slots dimensions
The dimensions of slots in granting shall be
selected having regard to the hydraulic capacity
and the slots shall be evenly distributed over
the clear area. The water way area shall not be
less than 30% of the clear area and shall be
given in the manufacturer's catalogue.
7.16
Frame depth
The depth of the complete frame of manhole or
gully tops of class D 400, E 600 and F 900 shall
be at least 100 mm.
Testing
Gully tops and manhole tops shall be tested as
complete units in their condition of service.
Compliance with the loading requirements for the
appropriate class be determined by the loading
test.
8.1 Test Loads
For Gully tops and manhole tops with a clear
opening equal to or greater than 250 mm, the
test load is shown in the table 6 for each
class. where the clear opening is less than 250
mm, the test load shall be that shown in tables
6, multiplied by CO/250.
|